GSW Class 15kW-50kW Yanmar

GRW Class Yanmar Industrial Towable Generator

Milbank PowerGen|Generators proudly announces the Industrial Standby Generator line of water cooled Yanmar 15kW - 50kW models.

This series provides the most professional way to fulfill small power requirements with highest reliability and excellent performance.

Features

Features

  • STAMFORD alternator
  • Water cooled
  • Automatic Controller
  • Internal residential muffler
  • Detachable central lifting point
  • Completely sealed drip pan
  • Complete with engine and battery liquids
  • Manual oil drain pump
  • Heavy duty galvanised skids (optional)
  • Baseframe can be moved with hand pallet truck
  • Standard 8 hour tank (varies by model)
  • EPA tier compliant
  • ATS, trailers, base tanks among other features available optionally

Models

Models

   Model Number GSW15Y GSW25Y GSW35Y GSW50Y

Note: Technical characteristics listed are not inclusive of any product customizations and the producer reserves the right to modify them for innovations without prior notice.


PRIME POWER PRP

14 kW
(17 kVA)

18 kW
(23 kVA)
31 kW
(39 kVA)
42 kW
(52 kVA)
EMER POWER LTP 15 kW
(19 kVA)
20 kW
(25 kVA)
32 kW
(40 kVA)
42 kW
(53 kVA)
Voltage 480/277 Volt 480/277 Volt 480/277 Volt 480/277 Volt
Frequency 60 Hz 60 Hz 60 Hz 60 Hz
Power factor 0.8 Cos φ 0.8 Cos φ 0.8 Cos φ 0.8 Cos φ

PRIME POWER PRP 14 kW
(17 kVA)
18 kW
(23 kVA)
29 kW
(36 kVA)
39 kW
(49 kVA)
EMER POWER LTP 15 kW
(19 kVA)
20 kW
(25 kVA)
30 kW
(37 kVA)
40 kW
(51 kVA)
Voltage 208/120 Volt 208/120 Volt 208/120 Volt 208/120 Volt
Frequency 60 Hz 60 Hz 60 Hz 60 Hz
Power factor 0.8 Cos φ 0.8 Cos φ 0.8 Cos φ 0.8 Cos φ

PRIME POWER PRP 14 kW
(17 kVA)
17.5 kW
(17.5 kVA)
27.4 kW
(27.4 kVA)
38 kW
(38 kVA)
EMER POWER LTP 15 kW
(19 kVA)
19 kW
(19 kVA)
30 kW
(30 kVA)
42 kW
(42 kVA)
Voltage 208/120 Volt 240/120 Volt 240/120 Volt 240/120 Volt
Frequency 60 Hz 60 Hz 60 Hz 60 Hz
Power factor 1 Cos φ 1 Cos φ 1 Cos φ 1 Cos φ

Tank capacity 21 US Gallons 21 US Gallons 21 US Gallons 21 US Gallons
Autonomy (III) (75% PRP) 22.0 h 16.5 h 9.6 h 7.3 h
Autonomy (III) (100% PRP) 16.5 h 12.4 h 7.2 h 5.5 h
Dimensions (LxWxH) 70.9" x 32.7" x 51.2" 70.9" x 32.7" x 51.2" 78.7" x 36.2" x 51.2" 78.7" x 36.2" x 57.3"
Weight (dry) 1,544 lbs 1,786 lbs 2,099 lbs 2,258 lbs
DIESEL ENGINE Yanmar 3TNV88 Yanmar 4TNV88 Yanmar 4TNV98 Yanmar 4TNV98T
Exhaust emissions EPA IV EPA IV EPA IV EPA IV
Cooling system Water Water Water Water
Speed 1800 rpm 1800 rpm 1800 rpm 1800 rpm
Displacement 100.2 cu. in. 133.6 cu. in. 202.5 cu. in. 202.5 cu. in.
Cylinders and disposition 3 line n° disp. 4 line n° disp. 4 line n° disp. 4 line n° disp.
Aspiration Natural Natural Natural Turbo
Engine power PRP 20 bhp 29 bhp 55 bhp 67 bhp
Engine power LTP 22 bhp 32 bhp 60 bhp 74 bhp
Fuel cons (III) (75% load PRP) 0.9 gal/h 1.2 gal/h 2.2 gal/h 2.8 gal/h
Fuel cons. (III) (100% load PRP) 1.2 gal/h 1.7 gal/h 2.9 gal/h 3.8 gal/h
Specific consumption PRP 0.397 lb/hph 0.397 lb/hph 0.363 lb/hph 0.386 lb/hph
Engine governor (standard) Mechanical Mechanical Electronic Electronic
SYNCH. ALTERNATOR STAMFORD BCI184E
STAMFORD BCI184E (F, 1ph)
STAMFORD BCI184G (J, 1ph)
STAMFORD BCI184J (UCI 224D, 1ph)
Power at 27ºC (480V) 24 Kwe
(30 kVA)
24 Kwe
(30 kVA)
31 Kwe
(39 kVA)
42 Kwe
(52 kVA)
Power at 27ºC (208V) 22 Kwe
(28 kVA)
22 Kwe
(28 kVA)
29 Kwe
(36 kVA)
39 Kwe
(49 kVA)
Power at 27ºC (240V) 13 Kwe
(16 kVA)
13 Kwe
(16 kVA)
16 Kwe
(20 kVA)
22 Kwe
(27 kVA)
Insulation class H H H H
Mechanical protection IP23 IP23 IP23 IP23
Voltage regulation Electronic / 1.5% Electronic / 1.5% Electronic / 1,5% Electronic / 1.5%

Control Panel

Control Panel

Automatic Control Panel (ACP)

  • Automatic control panel mounted on the genset, complete with
    digital control unit AC01 for monitoring, control and protection of the
    generating set.
  • Instrumentation (Digital) – Generator set voltage (3 phases), Mains
    voltage, Generator set frequency, Generator set current (3 phases),
    Battery voltage, Power (kVA - kW - kVAr), Power factor, Hour counter,
    Engine rpm, Fuel level (%), Engine temperature.
  • Commands and Others – Six settings (Automatic test, Automatic
    starting, Engine locked, Mains contactor forced, Manual start, Genset
    contactor forced); Emergency stop button; Remote start capable;
    Acoustic alarm; Integrated battery charger.
  • Protections with Alarm – Engine protection (low fuel level, low oil
    pressure, high engine temperature); Genset protection (under/over
    voltage, overload, under/over frequency, start failure, under/over
    battery voltage, battery charge failure).
  • Protections with Shutdown – Engine protection (low fuel level, low
    oil pressure, high engine temperature); Genset protection (under/
    over voltage, overload, under/over battery voltage, battery charge
    failure); Circuit breaker and differential protection (optional).
  • Output and Sockets – Power cables connected to terminals board (external); Main lugs.
* Manual Starting: the preheating period begins automatically when
this position is selected. It is necessary to select again this position
to enable one more time the preheating period.

Supplements

Supplements

Genset Supplements

  • Note: Some available from factory only.
  • APM – PMG for Stamford alternator + MX321 AVR.
  • AFP – Automatic fuel transfer pump.
  • DCC – Different color canopy.
  • EEG – Engine electronic governor.
  • PHS – Engine preheat system.
  • RCG – Remote control by gsm.
  • GSB – Galvanized Skids Frame: Heavy duty galvanized skid to be installed under the genset. Easily transportable with fork lift.
  • SUB – Extended capacity sub-base fuel tank.
  • ATS – Automatic transfer switch.
  • TRL – Road Trailer. Trailer with or without extended run tank.

 
Banner