GRW Class 15kW-50kW Industrial Towable

GRW Class Yanmar Industrial Towable Generator

Milbank PowerGen|Generators proudly announces the Industrial Towable Generator line of water cooled Yanmar 15kW - 50kW models.

This series is designed for the most demanding power in general applications, ideal for rental operators. It features a modern design and low noise level.

Features

Features

  • STAMFORD alternator
  • Water cooling system
  • Power on rent specification
  • Internal residential muffler
  • Detachable lifting point
  • Large integrated fuel tank
  • Complete with engine and battery liquids
  • Manual oil drain pump
  • Oversized, rugged base for jobsite applications
  • EPA tier compliant
  • Voltage selector switch and external potentiometer
  • Easy to read analog gauges with engine protection system
  • Available with or without trailer

Models

Models

   Model NumberGRW15YGRW25YGRW35Y GRW50Y

Note: Technical characteristics listed are not inclusive of any product customizations and the producer reserves the right to modify them for innovations without prior notice.

PRIME POWER PRP - 18 kW
(23 kVA)
31 kW
(39 kVA)
42 kW
(52 kVA)
EMER POWER LTP - 20 kW
(25 kVA)
32 kW
(40 kVA)
42 kW
(53 kVA)
Voltage - 480/277 Volt 480/277 Volt 480/277 Volt
Frequency - 60 Hz 60 Hz 60 Hz
Power factor - 0.8 Cos φ 0.8 Cos φ 0.8 Cos φ
PRIME POWER PRP - 18 kW
(23 kVA)
29 kW
(36 kVA)
39 kW
(49 kVA)
EMER POWER LTP - 20 kW
(25 kVA)
30 kW
(37 kVA)
40 kW
(51 kVA)
Voltage - 208/120 Volt 208/120 Volt 208/120 Volt
Frequency - 60 Hz 60 Hz 60 Hz
Power factor - 0.8 Cos φ 0.8 Cos φ 0.8 Cos φ
PRIME POWER PRP 12 kW
(12 kVA)
18 kW
(18 kVA)
20 kW
(20 kVA)
27 kW
(27 kVA)
EMER POWER LTP 14 kW
(14 kVA)
20 kW
(20 kVA)
22 kW
(22 kVA)
30 kW
(30 kVA)
Voltage 240/120 Volt 240/120 Volt 240/120 Volt 240/120 Volt
Frequency 60 Hz 60 Hz 60 Hz 60 Hz
Power factor 1 Cos φ 1 Cos φ 1 Cos φ 1 Cos φ
Tank capacity 53 US Gallons 53 US Gallons 95 US Gallons 95 US Gallons
Autonomy (III) (75% PRP) 61.0 h 42.0 h 54.0 h 38.0 h
Autonomy (III) (100% PRP) 46.0 h 32.0 h 40.0 h 28.0 h
Dimensions (LxWxH) 74.8" x 35.7" x 53.5" 74.8" x 35.7" x 53.5" 82.7" x 38.8" x 62.4" 82.7" x 38.8" x 62.4"
Weight (dry) 1,993 lbs 2,174 lbs 2,286 lbs 2,438 lbs
DIESEL ENGINE Yanmar 3TNV88 Yanmar 4TNV88 Yanmar 4TNV98 Yanmar 4TNV98T
Exhaust emissions EPA IV EPA IV EPA IV EPA IV
Cooling system Water Water Water Water
Speed 1800 rpm 1800 rpm 1800 rpm 1800 rpm
Displacement 100.2 cu. in. 133.6 cu. in. 202.5 cu. in. 202.5 cu. in.
Cylinders and disposition 3 line n° disp. 4 line n° disp. 4 line n° disp. 4 line n° disp.
Aspiration Natural Natural Natural Turbo
Engine power PRP 22 bhp 29 bhp 55 bhp 67 bhp
Engine power LTP 24 bhp 32 bhp 60 bhp 74 bhp
Fuel cons (III) (75% load PRP) 0.9 gal/h 1.2 gal/h 2.2 gal/h 2.8 gal/h
Fuel cons. (III) (100% load PRP) 1.2 gal/h 1.7 gal/h 2.9 gal/h 3.8 gal/h
Specific consumption PRP 0.397 lb/hph 0.397 lb/hph 0.363 lb/hph 0.386 lb/hph
Engine governor (standard) Mechanical Mechanical Mechanical Mechanical
SYNCH. ALTERNATOR STAMFORD BCI164C Dedicated STAMFORD BCI184F STAMFORD BCI184G STAMFORD BCI184J
Power at 27ºC (480V) - 30 Kwe
(38 kVA)
31 Kwe
(39 kVA)
42 Kwe
(52 kVA)
Power at 27ºC (208V) - 27 Kwe
(34 kVA)
29 Kwe
(36 kVA)
39 Kwe
(49 kVA)
Power at 27ºC (240V) 14 Kwe
(14 kVA)
15 Kwe
(19 kVA)
16 Kwe
(20 kVA)
22 Kwe
(27 kVA)
Insulation class H H H H
Mechanical protection IP23 IP23 IP23 IP23
Voltage regulation Electronic / 1.5% Electronic / 1.5% Electronic / 1.5% Electronic / 1.5%

Control Panel

Control Panel

Manual Control Panel (MCP)

  • Manual control panel mounted on the genset, with analog instrumentation, and protected through door with lockable handle.
  • Instrumentation (Analog) – Voltmeter, Ammeter, Frequency meter, Hours-counter, Fuel level indicator, Oil pressure indicator, Engine temperature indicator.
  • Commands and Others – Start/stop selector switch with key, Emergency stop button, Potentiometer for adjusting the output voltage, Six wire multipin connector for external remote start/stop signal and battery charger feeding.
  • Protections with Alarm – Engine protections: low fuel level, low oil pressure, high engine temperature, battery charger failure.
  • Protections with Shutdown – Engine protection unit (MC-01): low fuel level, low pressure oil, high engine temperature, battery charger failure. Circuit breaker protection.
  • Output and Sockets – Power cables connected to terminals board (external); Main lugs.
  • GRW15Y - GRW50Y:
    • 2 x 120V 20A 2P+T NEMA (duplex with GFCI)
    • 1 x 240/120V 30A 2P+T NEMA (twistlock)
    • 1 x 240/120V 50A 2P+T NEMA (twistlock)

Supplements

Supplements

Genset Features

  • VSS – Voltage Selector Switch: Rotary switch to reconnect the alternator for different output voltages from three phase to single phase - star (III) / parallel star (III) / zig-zag (II).
  • KRT – Rental Kit: Includes battery switch, fuel filter water separator, and three-way valve.
  • Skid Base – Heavy duty, oversized skid base for protection and versatility on the jobsite. Easily transportable with fork lift

Genset Supplements

  • Note: To be installed during manufacturing process.
  • EFT – Extended capacity sub-base fuel tank.
  • TRL – DOT Approved Road Trailer.
  • Cold Starting Aids – Blockheaters and battery warmers are available. Blockheaters and battery warmers are available.

 
Banner
Banner
Banner